| Parameter Name | Description | Units | Range |
|---|---|---|---|
| Engine RPM | Indicates engine revolutions per minute. | RPM | 0-18000 |
| Cylinder Head Temperature Voltage | Voltage value of the Cylinder Head Temperature Sensor. | V | 0 - 5 |
| Ignition Key Battery Voltage | Voltage value of the Ignition Switch or key battery voltage. | V | 10 - 17 |
| Relay Battery Voltage | Voltage value of the main relay battery voltage. | V | 4 - 20 |
| Intake Air Temperature Sensor Voltage | Voltage value of internal thermistor internal in throttle body for Intake Air Temperature. | V | 0 - 5 |
| Manifold Air Pressure Sensor 1 Voltage | Voltage value of MAP sensor internal in throttle body. | V | 0.5 - 4.5 |
| Hand Throttle Input Sensor Voltage | Voltage value of Hand Throttle Input Sensor (potentiometer) after 5v signal from ECU. | V | 0 - 5 |
| Throttle Position Sensor 1 Voltage | Signal voltage of throttle body flap position sensor 1 internal in throttle body. | V | 0 - 5 |
| Throttle Position Sensor 2 Voltage | Signal voltage of throttle body flap position sensor 2 internal in throttle body. | V | 0 - 5 |
| Low Oil Pressure Switch State | Oil pressure "low level" state detected. Oil pressure switch is normally closed and opens at 10-18 PSI. | On /Off | On /Off |
| Ambient Air Pressure | Measured Ambient Air Pressure internal in throttle body. | InHg | 0-75 |
| Manifold Air Pressure | Measured Manifold Air Pressure internal in throttle body. | InHg | 0-75 |
| Mass Air Flow | Calculated mass air flow in throttle body. | mg/tdc | 0 - 1023 |
| Throttle Position Sensor | Degrees of throttle body flap | °TPS | 0-85 |
| RPM Limit | Engine RPM limitation | RPM | |
| Advance Spark | Degrees of advancement of ignition spark. | °CRK | -30 to 90 |
| Injection Time | Injection time of fuel injectors. | ms | 0-262 |
| Idle RPM | Set Idle RPM - Set at factory | RPM | |
| MIL Status | Indicates status Malfunction Indicator Light if illuminated. | On /Off | On /Off |
| Injection Mode Status | Status of the different fuel injection modes. | Disabled/ Static / Imm Preinjection/ Phased Preinjection/ Sequental Not Phased/ Sequental Phased | Disabled/ Static / Imm Preinjection/ Phased Preinjection/ Sequental Not Phased/ Sequental Phased |
| Ignition Timing Status | Status of ignition mode. | Not Phased/ Phased | Not Phased/ Phased |
| Engine State | General engine operating states | Engine Stopped/ Start/ Idle Speed/ Part Load/Trailing Throttle/ Trailing Throttle Fuel Cut Off | Engine Stopped/ Start/ Idle Speed/ Part Load/Trailing Throttle/ Trailing Throttle Fuel Cut Off |
| CPS Synchronization | Status of Top Dead Center synchronization determined by crankshaft position sensor reading of flywheel timing ring. | No/ Yes | No/ Yes |
| TPS Sensor 1 Lower Adaption Value | Voltage value of throttle position sensor 1 to determine throttle position by a two-channeled sensor system (Potentiometer) internal in throttle body. | V | 0 - 5 |
| TPS Sensor 1 Lower Adaption Value | Voltage value of throttle position sensor 1 to determine throttle position by a two-channeled sensor system (Potentiometer) internal in throttle body. | V | 0 - 5 |
| TPS Sensor 2 Lower Adaption Value | Voltage value of throttle position sensor 2 to determine throttle position by a two-channeled sensor system (Potentiometer) internal in throttle body. | V | 0 - 5 |
| Engine Run Time | Overall engine operating hour counter since last ECU sw update. | H | |
| Engine Torque Static At Clutch | Calculated static engine torque at clutch. | ft-lb | |
| Fuel Pump State | State for electrical fuel pump | On / Off/ Prime | On / Off/ Prime |
| Cut Out Detection | Cut Out Detection from a switch (Ex. Operator Presence Switch). | On /Off | On /Off |
| Number of Clear Failure Memory | Number of failure memory clear events | ||
| Engine Speed Operating Limit 1 | Engine speed operating limit 1 - Set at factory | RPM | 1550 |
| Engine Speed Operating Limit 2 | Engine speed operating limit 2 - Set at factory | RPM | 2000 |
| Engine Speed Operating Limit 3 | Engine speed operating limit 3 - Set at factory | RPM | 2500 |
| Engine Speed Operating Limit 4 | Engine speed operating limit 4 - Set at factory | RPM | 3000 |
| Engine Speed Operating Limit 5 | Engine speed operating limit 5 - Set at factory | RPM | 3500 |
| Engine Speed Operating Limit 6 | Engine speed operating limit 6 - Set at factory | RPM | 4000 |
| Engine Stop Request | Engine Stop request | On /Off | On /Off |
| Main Relay State | State of Main Power Relay | On /Off | On /Off |
| Engine Speed Range 1 Minute Counter | Minute counter for engine speed range 1. | min | |
| Engine Speed Range 2 Minute Counter | Minute counter for engine speed range 2. | min | |
| Engine Speed Range 3 Minute Counter | Minute counter for engine speed range 3. | min | |
| Engine Speed Range 4 Minute Counter | Minute counter for engine speed range 4. | min | |
| Engine Speed Range 5 Minute Counter | Minute counter for engine speed range 5. | min | |
| Engine Speed Range 6 Minute Counter | Minute counter for engine speed range 6. | min | |
| Cylinder Head Temperature | Calculated Cylinder Head Temperature | °F | -40 to 420 |
| Intake Air Temperature | Calculated Intake Air Temperature | °F | -40 to 420 |
| Ambient Pressure Voltage | Calculated value of ambient pressure acquisition sensor internal in throttle body. | V | 0.5 - 4.5 |
| Operator Presence Switch Voltage | Voltage value of Operator Presence Switch. | V | 0-5 |
| Electronic Throttle Control PWM | Duty cycle of ETC actuator control. | % | -100 to 100 |
| ECU Reference Voltage 1 | Voltage value of sensor power supply voltage 1. | V | 0-5 |
| ECU Reference Voltage 2 | Voltage value of sensor power supply voltage 2. | V | 0-5 |
| Load Operating Limit 1 | Load operating limit 1 - Set at factory | % | 0 |
| Load Operating Limit 2 | Load operating limit 2 - Set at factory | % | 5 |
| Load Operating Limit 3 | Load operating limit 3 - Set at factory | % | 15 |
| Load Operating Limit 4 | Load operating limit 4 - Set at factory | % | 40 |
| Load Operating Limit 5 | Load operating limit 5 - Set at factory | % | 65 |
| Load Operating Limit 6 | Load operating limit 6 - Set at factory | % | 85 |
| Load Operating Limit 7 | Load operating limit 7 - Set at factory | % | 100 |
| Load Range 1 Counter | Minute counter for Load Range 1. | min | |
| Load Range 2 Counter | Minute counter for Load Range 2. | min | |
| Load Range 3 Counter | Minute counter for Load Range 3. | min | |
| Load Range 4 Counter | Minute counter for Load Range 4. | min | |
| Load Range 5 Counter | Minute counter for Load Range 5. | min | |
| Load Range 6 Counter | Minute counter for Load Range 6. | min | |
| Low Oil Pressure Counter | Counter of low oil pressure input from Low Oil Pressure Switch when engine RPM is 1500 or above. | ||
| Max Cylinder Head Temperature Recorded | Max cylinder head temperature recorded. | °F | -40 to 420 |
| Min Cylinder Head Temperature Recorded | Min cylinder head temperature recorded. | °F | -40 to 420 |
| Max Intake Air Temp Recorded | Max intake air temperature recorded. | °F | -40 to 420 |
| Min Intake Air Temp Recorded | Min intake air temperature recorded. | °F | -40 to 420 |
| Max Batt Voltage Recorded | Max battery voltage recorded. | V | 4 - 20 |
| Min Batt Voltage Recorded | Min battery voltage recorded. | V | 4 - 20 |